The platform you build for decides which native libraries of TX Text Control your deployment must contain. An x86 build needs the 32-bit set, an x64 build the 64-bit set, and an AnyCPU build whichever set matches the Windows it lands on. Here is what each configuration means for the files you ship and how to publish a .NET application for one platform.

### What Each Configuration Deploys

| Configuration | Runs as | Native libraries to deploy | .NET target runtime |
|---|---|---|---|
| x86 | A 32-bit process, on 32-bit and 64-bit Windows | The 32-bit set: *runtimes/win-x86/native* of the package, *Assembly\\bin* of the setup | `win-x86` |
| x64 | A 64-bit process | The 64-bit set: *runtimes/win-x64/native* of the package, *Assembly\\bin64* of the setup | `win-x64` |
| AnyCPU | A process with the bitness of the Windows it runs on | The set that matches the host: 32-bit on 32-bit Windows, 64-bit on 64-bit Windows | Depends on the target machines |

The managed assemblies are the same in every configuration. Only the native libraries and the [Visual C++ runtime](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/vc-runtime/llms-full.txt) follow the bitness.

Which configuration suits your application, and how to create x86 and x64 configurations in Visual Studio, is described in [Choose a Build Configuration](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/installation/requirements/32-bit-64-bit/#choose-a-build-configuration). For AnyCPU, the deployment has to know the bitness of the target machine.

### Publish a .NET Application for One Platform

A .NET application gets the native libraries of one platform when you publish it with the target runtime of the table, in the publish settings of Visual Studio or with `-r` of `dotnet publish`, as [Publishing .NET Applications](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/dotnet/llms-full.txt) shows. Without a target runtime, the output keeps both sets, as [Where the Files Go](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/assemblies/#where-the-files-go) describes. The package contains native libraries for `win-x86` and `win-x64` only, so these are the two target runtimes for an application with TX Text Control.

### Deploy a .NET Framework Application for One Platform

A .NET Framework application references the managed assemblies of the setup and ships the native libraries you copy next to it:

- For an **x86** build, copy the files of *Assembly\\bin*.
- For an **x64** build, copy the files of *Assembly\\bin64*.
- For an **AnyCPU** build, copy the set that matches the bitness of the target machine. An installer that serves 32-bit and 64-bit machines has to decide at installation which set it installs.

Never put both sets into the application folder: their files have the same names. [Deploying .NET Framework Applications](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/dotnet-framework/llms-full.txt) covers the rest of the deployment.

### When the Bitness Doesn't Match

A process that doesn't find the native libraries of its own bitness can't start the engine of TX Text Control. Typical causes are an AnyCPU build that runs as a 64-bit process where only the 32-bit set was deployed, and an installer that still copies the files of another configuration. [Native Libraries and Architecture Mismatches](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/troubleshooting/native-libraries/llms-full.txt) lists the error messages and the fixes.

### Related Pages

- [32-bit and 64-bit Applications](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/installation/requirements/32-bit-64-bit/llms-full.txt): why bitness matters and how to set up the configurations.
- [Managed Assemblies and Native Libraries](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/assemblies/llms-full.txt): the files of each set.
- [Visual C++ Runtime Dependencies](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/vc-runtime/llms-full.txt): the runtime of the same bitness.

---

## Nearby

- **Previous:** [Visual C++ Runtime Dependencies](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/vc-runtime/llms-full.txt)
- **Next:** [Publishing .NET Applications](https://docs.textcontrol.com/tx-text-control-dotnet-winforms/deployment/dotnet/llms-full.txt)